Add to Cart
Custom Made XLPE Insulated High Voltage Cable Underground
TABLE B.5 TECHNICAL DATA FOR 110KV TO BE FILLED BY THE TENDERER |
|||
No. |
Description |
Data |
Supplier |
1 |
producer |
Hebei New Baofeng Wire & Cable Co.,Ltd. |
|
2 |
Applied standard for testing |
SRPS IEC60840 |
IEC60840 |
3 |
Cable Type Designation |
SRPS N.CO.006 SRPS HD 632 S2(Part4-Section C) |
|
4 |
Norminal system voltage |
110KV |
110KV |
5 |
Rated phase voltage |
64KV |
64KV |
6 |
Rated current |
857A |
862A |
7 |
conductor |
|
|
Number of cores |
one |
one |
|
Material |
AL |
AL |
|
Conductor cross-section |
1000mm2 |
1000mm2 |
|
8 |
Conductor screen |
|
|
Material |
|
semi-conductive XLPE |
|
Thickness |
mm |
1.5 |
|
9 |
Insulation |
|
|
Material |
XLPE |
Superclean XLPE |
|
Thickness |
min.15 mm |
16.0 |
|
Cross-section |
mm2 |
3050 |
|
10 |
Semi-conduction screen |
|
|
Material |
|
semi-conductive XLPE |
|
Thickness |
mm |
1.2 |
|
Cross-section |
mm2 |
280 |
|
11 |
Eletrical proctection |
|
|
Material |
Cu |
Cu |
|
Cross-section |
95mm2 |
95mm2 |
|
thickness |
mm |
0.1 |
|
Diameter |
mm |
1.5 |
|
12 |
sheath |
|
|
material |
PE |
PE |
|
thickness |
mm |
4.5 |
|
13 |
Cable |
|
|
External cable diameter |
mm |
92.1 |
|
weight per meter |
kg/m |
8720 |
|
Maximum length on the drum |
m |
1000 |
|
14 |
Drum |
|
FULL STEEL DRUM |
Drum diameter |
|
3800 |
|
Drum width |
|
2200 |
|
Drum weight |
|
1800 |
|
15 |
minimum bending radius |
mm |
1650 |
16 |
minimum bending radius |
mm |
1850 |
during installation |
|||
17 |
permissible pulling force |
KN |
40.0 |
18 |
Delivery length per drum |
mm |
1000 |
18 |
Electrical characteristics |
|
|
Test voltage |
KV |
160 |
|
Maximum operating voltage |
KV |
126 |
|
impulse withstand voltage |
KV |
550 |
|
Rated frequency |
50HZ |
50HZ |
|
Conductor DC resistance at 20℃ |
Ω/km |
0.0291 |
|
conductor AC resistance at 90℃ |
Ω/km |
0.0402 |
|
Cable capacitance |
μF/km |
0.273 |
|
Cable inductance for trefoil formation |
mH/km |
0 |
|
Postitive sequence impedance of cable |
Ω/km |
0.0391 + j 0.206 |
|
Zero sequence impedance of cable |
Ω/km |
0.0661 + j 0.311 |
|
Maximum electrical stress |
kV/mm |
5.39 |
|
Conductor losses per phase |
kW/km |
29.52 |
|
Dielectric losses per phase |
kW/km |
0.28 |
|
Total losses |
kW/km |
29.80 |
|
Factor of losses at 20℃ 50HZ |
% |
0.85 |
|
19 |
current carrying capacity trefoil formation |
|
|
cables in ground |
A |
862 |
|
cables in air |
A |
1038 |
|
20 |
Earth fault current |
kA |
60.8 |
Earth fault duration |
sec |
3 |
|
21 |
Permissible overload |
A |
1316 |
22 |
Testing standard |
SRPS IEC 60840 |
IEC 60840 |
23 |
|
|
IEC60840 JDL266 2010 |
testing standard applied |
Number,date of issue, |
Quality inspection and testing |
|
Type test certificate |
issuing laboratory |
centre of Electric Equipment |
|
|
|
Ministry of Electric Power |
|
TABLE B 6.2a TECHNICAL DATA FOR CABLE TERMINATIONS FOR CONNECTING TO |
|||
SF6 SWITCHGEAR TO BE FILLED BY THE TENDERER |
|||
No. |
Description |
Data |
Supplier |
1 |
Producer |
ChangLan Electric Technology Co.,Ltd |
|
2 |
Type designation |
|
|
3 |
Applied Standard |
IEC 60859 |
IEC 60859 |
4 |
Rated voltage of the equipment |
123kv |
123KV |
5 |
rated frequency |
50HZ |
50Hz |
6 |
Power freuency withstand |
230KV |
230KV |
voltage 1min |
|||
7 |
impulse withstand voltage |
550kv |
550kv |
(1,2/50) |
|||
8 |
termination length |
mm |
1307 |
9 |
total weight of the termination |
kg |
62 |
10 |
Type test certificate |
Number,date of issue |
L1026,May 13th,2009 |
issuing laboratory |
Quality inspection and testing centre of Electric Equipment Ministry of Electric Power |
||
|
|||
TABLE B.6.2b TECHNICAL DATA FOR CABLE TERMINATIONS FOR CONNECTING TO |
|||
110KV OUTDOOR SWITCHGEAR TO BE FILLED BY THE TENDERER |
|||
No. |
Description |
Data |
Supplier |
1 |
Producer |
ChangLan Electric Technology Co.,Ltd |
|
2 |
Type designation |
|
|
3 |
Applied Standard |
IEC 60840 |
IEC 60840 |
4 |
Rated voltage of the equipment |
123kv |
123kV |
5 |
rated frequency |
50HZ |
50HZ |
6 |
Power freuency withstand |
230KV |
230KV |
voltage 1min |
|||
7 |
impulse withstand voltage |
550kv |
550kv |
(1,2/50) |
|||
8 |
termination length |
mm |
2130 |
9 |
total weight of the termination |
kg |
130 |
10 |
Type test certificate |
Number,date of issue |
L1026,May 13th,2009 |
issuing laboratory |
Quality inspection and testing centre of Electric Equipment Ministry of Electric Power |
||
TABLE B.6.3 TECHNICAL DATA FOR CABLE JOINTS TO BE FILLED BY THE TENDERER |
|||
No. |
Description |
Data |
Supplier |
1 |
Producer |
ChangLan Electric Technology Co.,Ltd |
|
2 |
Type designation |
|
|
3 |
Applied Standard |
SRPS IEC 60840 |
IEC 60840 |
4 |
Rated voltage of the equipment |
123kv |
123kV |
5 |
rated frequency |
50HZ |
50HZ |
6 |
Power freuency withstand |
230KV |
230KV |
voltage 1min |
|||
7 |
impulse withstand voltage |
550kv |
550kv |
(1,2/50) |
|||
8 |
creepage distance for the pollution |
|
|
levelⅡaccording to |
1X1000/95mm2 |
3906mm |
|
SRPS IEC 60815 |
|
|
|
9 |
joint length |
mm |
1485 |
10 |
total weight of the termination |
kg |
76 |
11 |
Type test certificate |
Number,date of issue |
L1026,May 13th,2009 |
issuing laboratory |
Quality inspection and testing centre of Electric Equipment Ministry of Electric Power |
NOTE: THE TECHNICAL DATA FOR ACCESSORIES IS FILLED BY ChangLan Electric Technology Co.,Ltd,BUT OFFERED BY HEBEI NEW BAOFNG WIRE AND CABLE CO.,LTD.